Nucleic Acids Research, 1990, Vol. 18, No. 3 569-575
© 1990
MOLECULAR BIOLOGY |
Molecular detrapping and band narrowing with high frequency modulation of pulsed field electrophoresis
1Xerox Research Centre of Canada 2660 Speakman Drive, Mississauga, Ontario L5K 2L1, Canada 2Biotechnology Research Institute 6100 Royalmount Avenue, Montreal, Quebec H4P 2R2, Canada
* To whom correspondence should be addressed
Received October 3, 1989. Revised December 11, 1989. Accepted December 11, 1989.
In high electric fields, megabase DNA fragments are found to be trapped, i.e. to enter or migrate in the gel only very slowly, if at all, leading to very broad electrophoretic bands and loss of separation. As a consequence, low electric fields are usually used to separate these molecules by pulsed field electrophoretic methods. We report here that high-frequency pulses eliminate the molecular trapping found in continuous fields. When high frequency pulses are used to modulate the longer pulses used in pulsed field electrophoresis, narrower bands result, and higher fields can be used. We suggest that this is due to effects that occur on the length scale of a single pore.
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
S. Gurrieri, S. B. Smith, and C. Bustamante Trapping of megabase-sized DNA molecules during agarose gel electrophoresis PNAS, January 19, 1999; 96(2): 453 - 458. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.-L. Viovy and T. Duke Solid Friction and Polymer Relaxation in Gel Electrophoresis Science, April 1, 1994; 264(5155): 112 - 113. [PDF] |
||||