Nucleic Acids Research, 2003, Vol. 31, No. 17 e105
© 2003 Oxford University Press
Kinetic Outlier Detection (KOD) in real-time PCR
1 Department of Chemistry and Bioscience, Chalmers University of Technology, Medicinargatan 7B, 405 30 Gothenburg, Sweden, 2 Department of Mathematical Statistics, Eklandagatan 86, 412 96, Gothenburg, Sweden and 3 TATAA Biocenter, Medicinargatan 7B, 405 30 Gothenburg, Sweden
*To whom correspondence should be addressed. Tel: +46 31 7733916; Fax: +46 31 7733910; Email: tzachi.bar{at}molbiotech.chalmers.se
Real-time PCR is becoming the method of choice for precise quantification of minute amounts of nucleic acids. For proper comparison of samples, almost all quantification methods assume similar PCR efficiencies in the exponential phase of the reaction. However, inhibition of PCR is common when working with biological samples and may invalidate the assumed similarity of PCR efficiencies. Here we present a statistical method, Kinetic Outlier Detection (KOD), to detect samples with dissimilar efficiencies. KOD is based on a comparison of PCR efficiency, estimated from the amplification curve of a test sample, with the mean PCR efficiency of samples in a training set. KOD is demonstrated and validated on samples with the same initial number of template molecules, where PCR is inhibited to various degrees by elevated concentrations of dNTP; and in detection of cDNA samples with an aberrant ratio of two genes. Translating the dissimilarity in efficiency to quantity, KOD identifies outliers that differ by 1.31.9-fold in their quantity from normal samples with a P-value of 0.05. This precision is higher than the minimal 2-fold difference in number of DNA molecules that real-time PCR usually aims to detect. Thus, KOD may be a useful tool for outlier detection in real-time PCR.
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
J. M. Ruijter, C. Ramakers, W. M. H. Hoogaars, Y. Karlen, O. Bakker, M. J. B. van den Hoff, and A. F. M. Moorman Amplification efficiency: linking baseline and bias in the analysis of quantitative PCR data Nucleic Acids Res., April 1, 2009; 37(6): e45 - e45. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. B. Shain and J. M. Clemens A new method for robust quantitative and qualitative analysis of real-time PCR Nucleic Acids Res., August 1, 2008; 36(14): e91 - e91. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Granado, A. I. Martin, M. Lopez-Menduina, A. Lopez-Calderon, and M. A. Villanua GH-releasing peptide-2 administration prevents liver inflammatory response in endotoxemia Am J Physiol Endocrinol Metab, January 1, 2008; 294(1): E131 - E141. [Abstract] [Full Text] [PDF] |
||||
![]() |
M Granado, A I Martin, T Priego, A Lopez-Calderon, and M A Villanua Tumour necrosis factor blockade did not prevent the increase of muscular muscle RING finger-1 and muscle atrophy F-box in arthritic rats. J. Endocrinol., October 1, 2006; 191(1): 319 - 326. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. Suslov and D. A. Steindler PCR inhibition by reverse transcriptase leads to an overestimation of amplification efficiency Nucleic Acids Res., November 27, 2005; 33(20): e181 - e181. [Abstract] [Full Text] [PDF] |
||||


