Skip Navigation

This Article
Right arrow Abstract Freely available
Right arrow Print PDF (102K) Freely available
Right arrow Supplementary Material
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Commercial Re-use Guidelines
for Open Access NAR Content
Google Scholar
Right arrow Articles by Rutledge, R. G.
Right arrow Articles by Côté, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rutledge, R. G.
Right arrow Articles by Côté, C.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Nucleic Acids Research, 2003, Vol. 31, No. 16 e93
© 2003 Oxford University Press

Mathematics of quantitative kinetic PCR and the application of standard curves

R. G. Rutledge* and C. Côté

Natural Resources Canada, Canadian Forest Service, Laurentian Forestry Centre, 1055 du P.E.P.S., PO Box 3800, Sainte-Foy, Quebec G1V 4C7, Canada

*To whom correspondence should be addressed. Tel: +1 418 648 2582; Fax: +1 418 648 5849; Email: brutledge{at}cfl.forestry.ca

Received as resubmission May 15, 2003; Accepted June 18, 2003


    ABSTRACT
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 SUPPLEMENTARY MATERIAL
 REFERENCES
 
Fluorescent monitoring of DNA amplification is the basis of real-time PCR, from which target DNA concentration can be determined from the fractional cycle at which a threshold amount of amplicon DNA is produced. Absolute quantification can be achieved using a standard curve constructed by amplifying known amounts of target DNA. In this study, the mathematics of quantitative PCR are examined in detail, from which several fundamental aspects of the threshold method and the application of standard curves are illustrated. The construction of five replicate standard curves for two pairs of nested primers was used to examine the reproducibility and degree of quantitative variation using SYBER® Green I fluorescence. Based upon this analysis the application of a single, well- constructed standard curve could provide an estimated precision of ±6–21%, depending on the number of cycles required to reach threshold. A simplified method for absolute quantification is also proposed, in which quantitative scale is determined by DNA mass at threshold.


    INTRODUCTION
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 SUPPLEMENTARY MATERIAL
 REFERENCES
 
Kinetic PCR (kPCR) allows quantification of a target DNA within a sample, with the advantage that sensitivity is independent of copy number (14). The key aspect differentiating kPCR from previous quantitative PCR methodologies is that target copy number is determined from the fractional cycle at which a threshold amount of amplicon DNA is reached (threshold cycle or Ct), set at a point where amplicon DNA just becomes detectable, but is still within the exponential phase of the amplification (57). This approach ensures that interfering factors associated with the late stages of amplification are minimized, and provides the potential for unprecedented precision for quantitative determinations.

Although several methods have been developed to measure Ct, all are based upon fluorescent monitoring of amplicon DNA generation (810). Absolute quantification can be achieved using a standard curve, constructed by amplifying known amounts of target DNA in a parallel group of reactions run under identical conditions to that of the sample (7,11). Standard curve preparation is both labour intensive and error prone, with quantitative accuracy being dependent on both the accuracy of DNA standard quantification and the quality of standard curve construction (1,12,13).

In this study, a detailed examination of the mathematics governing PCR yielded insights into the process of quantitative kPCR and into some of the fundamental aspects of the threshold method. This provided a foundation from which to examine the reproducibility of standard curve construction. Assessment of intra- and inter-run variation indicates that a substantial degree of precision can be achieved, even with the application of a single standard curve to multiple runs. An alternative approach is also proposed in which quantitative scale is determined by DNA mass at threshold, such that absolute quantification would only require determination of amplification efficiency.


    MATERIALS AND METHODS
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 SUPPLEMENTARY MATERIAL
 REFERENCES
 
The DNA standard consisted of a 218 bp amplicon produced by the K3/K2 primer pair (forward K3: GGCACCTC AGGAATGGGCTATTACAA and reverse K2: AGAATA ACACAGAAATCTGTAGGTGGAATTGAA) that was purified by chloroform extraction followed by isopropanol precipitation, and quantified by averaging three replicate A260 absorbance determinations conducted on two spectrophotometers. A second 102 bp amplicon was produced by pairing of K2 with another primer (forward K1: TCCTATGAGATTATGACGCATTTCTCCAAA) located near the center of the K3/K2 amplicon. The primer pair combinations of K3/K2 and the nested K1/K2 thus allowed the production of two different-sized amplicons (218 and 102 bp, respectively) using the same DNA standard dilution series.

PCR amplifications were conducted using QuantiTectTM Syber® Green PCR Kit (Qiagen Inc.) according to the manufacturer’s instructions, with 0.25 µM primers and a variable amount of DNA standard in a 35 µl final reaction volume. Thermocycling was conducted using an Opticon2 DNA Engine (MJ Research Inc.) initiated by a 15 min incubation at 94°C, followed by 45 cycles (90°C, 1 s; 62°C, 120 s) with a single fluorescent reading taken at the end of each cycle. Each run was completed with a melting curve analysis to confirm the specificity of amplification and lack of primer dimers. Ct values were determined by the Opticon2 software using a fluorescence threshold manually set to 0.0160 for all runs and exported into a MS Excel workbook (Microsoft Inc.) for analysis (available as Supplementary Material).


    RESULTS
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 SUPPLEMENTARY MATERIAL
 REFERENCES
 
Mathematics of quantitative kPCR
The basic equation describing PCR amplification is:

NC = N0·(E + 1)C1

where C is the number of thermocycles, E is amplification efficiency (also expressed as %E = E x100%), NC is the number of amplicon molecules and N0 is the initial number of target molecules.

In simple terms, each thermocycle produces an increase in NC in proportion to amplification efficiency, such that 100% efficiency produces a doubling in the number of amplicon molecules. Additionally, the quantity of NC present after any specific number of thermocycles is dependent on N0. Rearrangement of equation 1 provides the mathematical relationship upon which quantitative kPCR is based:

N0 = NC/(E + 1)C2

Quantification of NC thus allows N0 to be calculated if amplification efficiency is known. A major breakthrough for quantitative PCR came with the use of DNA fluorescence to monitor amplicon accumulation (3,5). Based upon this technique Higuchi et al. (5) developed an elegant method that simplifies NC determination, such that individual amplification reactions are compared at the point at which they contain identical amounts of amplicon DNA. This is accomplished by selecting a fluorescent threshold (Ft) from which the fractional thermocycle (Ct) is calculated that defines the theoretical point at which each amplification reaction reaches fluorescence threshold.

Under this ‘threshold’ method, NC becomes a constant such that equation 2 becomes:

N0 = Nt/(E + 1)Ct3

where Ct is the threshold cycle and Nt is the number of amplicon molecules at fluorescent threshold.

Absolute quantification can be achieved using a standard curve constructed by amplification of known amounts of target DNA and plotting the resulting Ct values against target DNA concentration. The mathematical basis of a standard curve can be derived by taking the logarithm of equation 3:

Log(N0) = Log(Nt) – Log[(E + 1)Ct]

Log(N0) = Log (Nt) – Log(E + 1)·Ct

Log(N0) = –Log(E + 1)·Ct + Log (Nt)4

Assuming E and Nt are constants, equation 4 has the general structure of a line (y = mx + b) such that plotting Log(N0) versus Ct produces a line with:

Slope = –Log(E + 1)

ES = 10–Slope – 15

and

Intercept = Log(Nt)

Nt = 10Intercept6

where ES is the slope-derived estimate of amplification efficiency.

Although the ability to derive amplification efficiency from the slope of a standard curve has been widely reported, it has not been generally recognized that the number of amplicon molecules at threshold can be directly determined from the intercept. It must also be stressed that these derivations are valid only if all PCR reactions have identical amplification efficiencies, and only if amplification efficiency is invariant over the number of thermocycles required to reach Ct.

Another important but often overlooked aspect of the threshold method is the interdependency of Ct and Nt on Ft, which has two important implications. First, Ct values generated from different amplification runs can be directly compared only if an identical Ft is used for each run. Second, the relationship between Nt and Ft is dependent on amplicon size. This is due to the fact that the underlying determinant of Ft is DNA fluorescence, which in turn has a linear relationship with DNA mass. As such Ft directly reflects DNA mass at threshold, which is related to Nt as described by:

Mt = (Nt·AS)/9.1 x 10117

where Mt is the DNA mass at threshold in nanograms, AS is the amplicon size in base pairs and 9.1 x 1011 is the number of single base pair molecules per nanogram.

A less obvious but potentially significant extension of this is that if Mt is known, Nt can be predicted for any amplicon of known size, if it is assumed that amplicon size and base pair composition do not significantly influence DNA fluorescence. To test the general utility of PCR mathematics for standard curve evaluation and to examine the effectiveness of Mt for predicting Nt, a series of replicate standard curves was constructed for two amplicons that differ significantly in size.

Experimental design for constructing replicate standard curves
Figure 1 is an example of the two types of graphic output generated by the instrument used in this study, and illustrates the two basic steps in quantitative kPCR using the threshold method, i.e. the selection of a fluorescent threshold from which Ct values are generated (Fig. 1A), followed by linear regression analysis of a Log(N0) versus Ct plot, from which ES and Nt are estimated (Fig. 1B).



View larger version (22K):
[in this window]
[in a new window]
 
Figure 1. Output of a typical amplification run used for construction of the standard curves in this study. Four replicate amplification reactions were conducted for each concentration of DNA standard, covering six magnitudes of target DNA concentration. (A) Plot of the log of reaction fluorescent versus thermocycle that provides a graphic representation for each amplification reaction, in which the linear region represents the exponential phase of the amplification. Fluorescent threshold provides the reference point from which the threshold cycle (Ct) is calculated. (B) The resulting standard curve generated by plotting the log of target DNA concentration versus threshold cycle. Linear regression analysis is used to determine the slope and intercept, which correspond, respectively, to the amplification efficiency and the number of amplicon molecules at threshold, as described by equation 4.

 
The major consideration for Ft selection is that it falls within the exponential phase of the amplification reaction, best illustrated by plotting log fluorescence versus cycle number (Fig. 1A). As long as Ft is within this log-linear region, the absolute value of Ft was found to have only a modest impact on the slope-derived estimate of amplification efficiency (data not shown). However, as outlined above, Ft does have a direct impact on both Ct and Nt such that Ft must be fixed if data from multiple runs are to be directly compared.

To evaluate the reproducibility and quantitative variation of the threshold method, five replicate standard curves were generated from two pairs of nested primers (K3/K2 and K1/K2, see Materials and Methods for additional details) using a DNA standard dilution series covering six magnitudes of target DNA concentration. The use of nested primers allowed two different-sized amplicons (218 and 102 bp, respectively) to be amplified side-by-side within the same run, using the same DNA standard dilution series. Intra- and inter-run variation could then be examined for each of the two amplicons, free of errors caused by variations in the DNA standard. Using an identical Ft for all runs, the average Ct of four replicate amplifications for each DNA concentration were used in the analysis (Table 1). A spreadsheet containing the individual Ct values and the calculations used for their analysis is provided as Supplementary Material.


View this table:
[in this window]
[in a new window]
 
Table 1. Ct data from five replicate amplification runs using two pairs of nested primers
 
Intra- and inter-run variation in Ct
As an initial step for evaluation of quantitative precision, the reproducibility of amplification under our experimental conditions was estimated, based upon the standard deviation in Ct values generated from replicate amplifications. Moreover, due to the exponential scale of Ct, the impact of its variation can be difficult to assess, and thus the standard deviations in Ct were also used to estimate the variation in percent molecules based upon the equation:

±%Molecules = [(E + 1)SD – 1] x100%8

where SD is the standard deviation in Ct generated from replicate amplifications.

Overall the standard deviation in Ct of replicate amplifications ranged from 0.036 to 0.367 cycles, with an average of 0.183 cycles (Table 1 and Supplementary Material). This corresponds to an estimated variation in molecules that ranges from ±2.3 to ±26.6% with an average of ±12.4%, using an amplification efficiency of 90% taken from the slope-based estimate of amplification efficiency determined below.

Based upon the average standard deviation produced from each individual run, estimates of the intra-run variation were similar for both amplicons, ranging from ±9.6% to 14.9% of molecules (runs 1–5, Table 1). When combined with inter-run variation, this increased to ±17.4 and ±21.3% of molecules for each amplicon, respectively, based upon averaging the standard deviation in Ct for each DNA concentration from all runs (‘Combined’, Table 1). These variations, although significant, indicate that Ct values have an acceptable level of reproduciblity over the six magnitudes of target DNA concentration that were examined.

Standard curve construction and evaluation
Evaluation of the quantitative variation between replicate standard curves was conducted by generating Nt and %ES values for each amplification run listed in Table 1. This was done by exporting the Ct values into a spreadsheet, and calculating the slope and intercept for each run using linear regression analysis of log(N0) versus Ct. Two methods were then used to assess the quantitative variation between the five replicate standard curves constructed for each of the two amplicons (Table 2).


View this table:
[in this window]
[in a new window]
 
Table 2. Summary of the linear regression analysis conducted for each amplification run listed in Table 1 and an evaluation of inter-curve variation
 
Examination of the absolute values of Nt and %ES revealed similar trends for both amplicons, with an inter-curve variation in %ES of ±2.2 and ±2.1%, and variation in Nt of ±19.0 and ±14.7%, respectively, as based upon their standard deviations (Table 2). Taken individually, the magnitude of variation in %ES and Nt suggests the resulting variation in N0 determination could be large. For example, for a Ct of 25 cycles, a ±2.2% variance in the estimate of amplification efficiency would produce an approximate ±33% variation in N0 that, when combined with the apparent ±19% variance in Nt, could produce an overall variation of about ±52% for N0. It must be noted, however, that further examination suggests that these estimates of variance are most certainly erroneous, due to an apparent intra-curve correlation between slope and intercept.

Comparing the %ES and Nt values generated from each individual standard curve reveals that for both amplicons, the curve that produced the highest %ES also produced the highest Nt (Table 2, K1/K2, run 2 and K3/K2, run 1). Similarly, the standard curves producing the lowest %ES also had the lowest Nt (Table 2, K1/K2, run 1 and K3/K2, run 5). Taken together, these trends suggest that variations in intercept and slope are not solely caused by inter-run variation in instrumentation and/or amplification, but also reflect an innate characteristic of linear regression in which variations in slope can be compensated for to some degree by a corresponding variation in intercept.

This can be best illustrated through an alternative approach to evaluating quantitative differences produced by replicate standard curves. As illustrated in Table 2, inter-curve variation can be estimated by comparing the calculated N0 for a series of simulated Ct values using equation 3. Thus, for the five standard curves constructed from the K1/K2 amplicon, the calculated N0 for Ct=10 cycles ranges from 3.67 x 107 to 4.64 x 107 molecules, with an average of 4.13 x 107 molecules and a standard deviation corresponding to ±8.7% of molecules (Table 2). Furthermore, a general increase in variation is observed with increasing Ct such that for Ct = 30 cycles, a variation of ±18.1% of molecules is produced. Very similar results were produced by the larger K3/K2 amplicon (Table 2).

Overall, this analysis demonstrates that quantitative variations produced by replicate standard curves can be relatively small, ranging in this study from a low of about ±6% to a high of about ±21% depending on the number of cycles needed to reach threshold. The observed inter-curve variation in the absolute values of slope and intercept also suggests that curve-based estimates of amplification efficiency and Nt require a larger data set than would normally be used for construction of a single standard curve. Indeed, the relative accuracy of the Nt estimates for each of the two amplicons can be tested through the correlation of their respective Mt values, as described by equation 7. Based upon the Nt values derived from each respective ‘combined’ data set, the estimated Mt values differ by 7.3% (Table 2). This provides support for both the optical precision of the instrumentation and similarity in the SYBER® Green I fluorescent characteristics of these two amplicons.


    DISCUSSION
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 SUPPLEMENTARY MATERIAL
 REFERENCES
 
Despite the extensive use of the threshold method for absolute quantification, there exists a paucity of studies that have examined the utility of the underlying mathematics. Furthermore, the general simplicity and widespread use of standard curves has led to the automation of quantitative determinations, which can obscure the mathematical principles upon which the analysis is based. Familiarity with the fundamentals of PCR mathematics cannot only yield important insights, but as well provide a foundation from which to address some of the major limitations of quantitative kPCR.

At the most basic level, the threshold method does not generally provide an effective indication of quantitative precision or accuracy. Although the standard deviation in Ct produced from replicate amplifications can provide an estimate of reproducibility, there is a general deficiency in reporting the errors associated with standard curve construction. This makes it difficult to evaluate the effectiveness of any specific quantitative determination, or of comparing results produced by different studies. As was demonstrated in this study, a basic assessment of standard curve construction can be conducted, if it is understood that slope and intercept are directly correlated to amplification efficiency and the number of amplicon molecules at threshold (Nt), respectively.

In this study, comparison of replicate standard curves revealed potentially large inter-curve variations, based upon the absolute values of slope and intercept. This initially led to the conclusion that this was caused by substantial inter-run variations in amplification and/or instrumentation. However, upon closer examination, an intra-curve correlation between slope and intercept became apparent, such that differences in slope are compensated for to a significant degree by corresponding differences in intercept.

This can be demonstrated through simple mathematical modeling, in which the initial number of target molecules (N0) is calculated for a series of simulated Ct values (equation 3, Table 2). This showed that despite the differences in the absolute values of amplification efficiency and Nt, the resulting N0 values generated by each standard curve were unexpectedly similar. Based upon this analysis the application of a single, well-constructed standard curve could provide an estimated precision of ±6–21% of molecules, depending on the number of cycles required to reach threshold.

Notwithstanding the interrelationship of slope and intercept, it must be stressed that the mathematics of PCR dictate that amplification efficiency and Nt are independent entities. In reality Nt is determined solely by the fluorescent threshold (Ft), and as such its value is independent of the parameters impacting PCR amplification. Indeed, this interrelationship between Nt and Ft has important practical implications, based on the principle that Ft does not directly reflect the number of amplicon molecules, but rather DNA mass at fluorescent threshold (Mt). This in turn dictates that Mt could be used to predict Nt for any amplicon of known size, if it is assumed that amplicon size and base composition do not significantly impact DNA fluorescence. Support for the validity of this assumption was provided by the Nt estimates generated from the two amplicons used in this study, for which the predicted Mt values differ by 7.3% (equation 7, Table 2).

The practical significance of this becomes apparent if it is noted that Nt is the sole determinant of scale (equation 3), the accuracy of which is dependent on the quantitative accuracy of the DNA standard used for standard curve construction. If, however, Mt can be used to predict Nt with sufficient precision, a common quantitative scale could be applied to all amplicons. In addition to circumventing the necessity of preparing a quantified DNA standard for each individual amplicon, the major source of variation in quantitative scale would become the optical precision of the instrument. Equally significant is that absolute quantification would be simplified, requiring only determination of amplification efficiency once Mt has been established.


    SUPPLEMENTARY MATERIAL
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 SUPPLEMENTARY MATERIAL
 REFERENCES
 
Supplementary Material is available at NAR Online.


    ACKNOWLEDGEMENTS
 
The authors thank Richard Hamelin, Krystyna Klimaszewska and Brian Boyle for helpful comments, and Pamela Cheers for editorial assistance. This research was supported by a grant from the National Biotechnology Strategy of Canada.


    REFERENCES
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 SUPPLEMENTARY MATERIAL
 REFERENCES
 

  1. Freeman,W.M., Walker,S.J. and Vrana,K.E. (1999) Quantitative RT-PCR: pitfalls and potential. Biotechniques, 26, 112–125.[Web of Science][Medline]

  2. Bustin,S.A. (2000) Absolute quantification of mRNA using real-time reverse transcription polymerase chain reaction assays. J. Mol. Endocrinol., 25, 169–193.[Abstract]

  3. Kang,J.J., Watson,R.M., Fisher,M.E., Higuchi,R., Gelfand,D.H. and Holland,M.J. (2000) Transcript quantitation in total yeast cellular RNA using kinetic PCR. Nucleic Acids Res., 28, e2.[Abstract/Free Full Text]

  4. Schmittgen,T.D. (2001) Real-time quantitative PCR. Methods, 25, 383–385.[CrossRef][Web of Science][Medline]

  5. Higuchi,R., Fockler,C., Dollinger,G. and Watson,R. (1993) Kinetic PCR analysis: real-time monitoring of DNA amplification reactions. Biotechnology, 11, 1026–1030.[CrossRef][Medline]

  6. Morrison,T.B., Weis,J.J. and Wittwer,C.T. (1998) Quantification of low-copy transcripts by continuous SYBR® Green I monitoring during amplification. Biotechniques, 24, 954–962.[Web of Science][Medline]

  7. Rasmussen,R. (2001) Quantification on the LightCycler. In Meuer,S., Wittwer,C. and Nakagawara,K. (eds), Rapid Cycle Real-time PCR, Methods and Applications. Springer Press, Heidelberg, pp. 21–34.

  8. Wittwer,C.T., Herrmann,M.G., Moss,A.A. and Rasmussen,R.P. (1997) Continuous fluorescence monitoring of rapid cycle DNA amplification. Biotechniques, 22, 130–138.[Web of Science][Medline]

  9. Wittwer,C., Ririe,K. and Rasmussen,R. (1998) Fluorescence monitoring of rapid cycle PCR for quantification. In Ferré,F. (ed.), Gene Quantification. Birkhäuser, Boston, MA, pp. 129–144.

  10. Giulietti,A., Overbergh,L., Valckx,D., Decallonne,B., Bouillon,R. and Mathieu,C. (2001) An overview of real-time quantitative PCR: applications to quantify cytokine gene expression. Methods, 25, 386–401.[CrossRef][Web of Science][Medline]

  11. Pfaffl,M.W. and Hageleit,M. (2001) Validities of mRNA quantification using recombinant RNA and recombinant DNA external calibration curves in real-time RT-PCR. Biotechnol. Lett., 23, 275–282.[CrossRef]

  12. Niesters,H.G.M. (2001) Quantitation of viral load using real-time amplification techniques. Methods, 25, 419–429.[CrossRef][Web of Science][Medline]

  13. Lehmann,U. and Kreipe,H. (2001) Real-time PCR analysis of DNA and RNA extracted from formalin-fixed and paraffin-embedded biopsies. Methods, 25, 409–418.[CrossRef][Web of Science][Medline]


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
J. Biol. Chem.Home page
L. Sturla, C. Fresia, L. Guida, S. Bruzzone, S. Scarfi, C. Usai, F. Fruscione, M. Magnone, E. Millo, G. Basile, et al.
LANCL2 Is Necessary for Abscisic Acid Binding and Signaling in Human Granulocytes and in Rat Insulinoma Cells
J. Biol. Chem., October 9, 2009; 284(41): 28045 - 28057.
[Abstract] [Full Text] [PDF]


Home page
J DAIRY SCIHome page
S. D. McCarthy, S. T. Butler, J. Patton, M. Daly, D. G. Morris, D. A. Kenny, and S. M. Waters
Differences in the expression of genes involved in the somatotropic axis in divergent strains of Holstein-Friesian dairy cows during early and mid lactation
J Dairy Sci, October 1, 2009; 92(10): 5229 - 5238.
[Abstract] [Full Text] [PDF]


Home page
Am J Trop Med HygHome page
L. A. Hill, J. B. Davis, G. Hapgood, P. I. Whelan, G. A. Smith, S. A. Ritchie, R. D. Cooper, and A. F. van den Hurk
Rapid Identification of Aedes albopictus, Aedes scutellaris, and Aedes aegypti Life Stages Using Real-time Polymerase Chain Reaction Assays
Am J Trop Med Hyg, December 1, 2008; 79(6): 866 - 875.
[Abstract] [Full Text] [PDF]


Home page
J. Biol. Chem.Home page
A. Paun, J. T. Reinert, Z. Jiang, C. Medin, M. Y. Balkhi, K. A. Fitzgerald, and P. M. Pitha
Functional Characterization of Murine Interferon Regulatory Factor 5 (IRF-5) and Its Role in the Innate Antiviral Response
J. Biol. Chem., May 23, 2008; 283(21): 14295 - 14308.
[Abstract] [Full Text] [PDF]


Home page
J Exp BotHome page
A. Lendvai, A. Pettko-Szandtner, E. Csordas-Toth, P. Miskolczi, G. V. Horvath, J. Gyorgyey, and D. Dudits
Dicot and monocot plants differ in retinoblastoma-related protein subfamilies
J. Exp. Bot., May 1, 2007; 58(7): 1663 - 1675.
[Abstract] [Full Text] [PDF]


Home page
J. Mol. Diagn.Home page
S. O. Hjelmevoll, M. E. Olsen, J. U. E. Sollid, H. Haaheim, M. Unemo, and V. Skogen
A Fast Real-Time Polymerase Chain Reaction Method for Sensitive and Specific Detection of the Neisseria gonorrhoeae porA Pseudogene
J. Mol. Diagn., November 1, 2006; 8(5): 574 - 581.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Microbiol.Home page
L. Cook, K. Sullivan, E. M. Krantz, A. Bagabag, and K. R. Jerome
Multiplex Real-Time Reverse Transcription-PCR Assay for Determination of Hepatitis C Virus Genotypes
J. Clin. Microbiol., November 1, 2006; 44(11): 4149 - 4156.
[Abstract] [Full Text] [PDF]


Home page
Nucleic Acids ResHome page
J. J. Yun, L. E. Heisler, I. I. L. Hwang, O. Wilkins, S. K. Lau, M. Hyrcza, B. Jayabalasingham, J. Jin, J. McLaurin, M.-S. Tsao, et al.
Genomic DNA functions as a universal external standard in quantitative real-time PCR
Nucleic Acids Res., July 13, 2006; 34(12): e85 - e85.
[Abstract] [Full Text] [PDF]


Home page
Plant Physiol.Home page
G. C. Briggs, C. F. Mouchel, and C. S. Hardtke
Characterization of the Plant-Specific BREVIS RADIX Gene Family Reveals Limited Genetic Redundancy Despite High Sequence Conservation
Plant Physiology, April 1, 2006; 140(4): 1306 - 1316.
[Abstract] [Full Text] [PDF]


Home page
Plant CellHome page
R. Sibout, A. Eudes, G. Mouille, B. Pollet, C. Lapierre, L. Jouanin, and A. Seguin
CINNAMYL ALCOHOL DEHYDROGENASE-C and -D Are the Primary Genes Involved in Lignin Biosynthesis in the Floral Stem of Arabidopsis
PLANT CELL, July 1, 2005; 17(7): 2059 - 2076.
[Abstract] [Full Text] [PDF]


Home page
Appl. Environ. Microbiol.Home page
B. Boyle, R. C. Hamelin, and A. Seguin
In Vivo Monitoring of Obligate Biotrophic Pathogen Growth by Kinetic PCR
Appl. Envir. Microbiol., March 1, 2005; 71(3): 1546 - 1552.
[Abstract] [Full Text] [PDF]


Home page
Nucleic Acids ResHome page
R. G. Rutledge
Sigmoidal curve-fitting redefines quantitative real-time PCR with the prospective of developing automated high-throughput applications
Nucleic Acids Res., December 15, 2004; 32(22): e178 - e178.
[Abstract] [Full Text] [PDF]


Home page
Nucleic Acids ResHome page
S. Swillens, J.-C. Goffard, Y. Marechal, A. de Kerchove d'Exaerde, and H. El Housni
Instant evaluation of the absolute initial number of cDNA copies from a single real-time PCR curve
Nucleic Acids Res., March 29, 2004; 32(6): e56 - e56.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Print PDF (102K) Freely available
Right arrow Supplementary Material
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Commercial Re-use Guidelines
for Open Access NAR Content
Google Scholar
Right arrow Articles by Rutledge, R. G.
Right arrow Articles by Côté, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rutledge, R. G.
Right arrow Articles by Côté, C.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?