Nucleic Acids Research Advance Access originally published online on October 26, 2006
Nucleic Acids Research 2007 35(Database issue):D805-D809; doi:10.1093/nar/gkl767
Nucleic Acids Research, 2007, Vol. 35, Database issue D805-D809
Published by Oxford University Press 2006
This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/2.0/uk/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
qPrimerDepot: a primer database for quantitative real time PCR
Wenwu Cui,
Dennis D. Taub1 and
Kevin Gardner*
Laboratory of Receptor Biology and Gene Expression, National Cancer Institute Bethesda, MD 20892-4605
1 Laboratory of Immunology, National Institute on Aging Baltimore, MD 21224, USA
*To whom correspondence should be addressed at National Institutes of Health, Advanced Technology Center, Room 134C, 8717 Grovemont Circle, Bethesda, MD 20892-4605, USA. Tel: +1 301 496 1055; Fax: +1 301 435 7558; Email: gardnerk{at}mail.nih.gov
Received June 3, 2006. Revised September 25, 2006. Accepted September 29, 2006.
 |
ABSTRACT
|
|---|
Gene expression studies employing high throughput real time
PCR methods require finding uniform conditions for optimal amplification
of multiple targets, often a daunting task. We developed a primer
database, qPrimerDepot, which provides optimized primers for
all human and mouse RefSeq genes. These primers are designed
to amplify desired templates under unified annealing temperature.
For most intron-bearing genes, primers flank one of the largest
introns thus minimizing background noise due to genomic DNA
contamination. The qPrimerDepot database can be accessed at
http://primerdepot.nci.nih.gov/ and
http://mouseprimerdepot.nci.nih.gov/.
 |
INTRODUCTION
|
|---|
Real time PCR (RT-PCR) can rapidly, reproducibly and quantitatively
determine changes in gene expression (
1). Although microarray
analysis can measure large scale gene expression levels simultaneously,
its hybridization-related variation often demands validation
by other methods. Routinely, RT-PCR is used to verify the observation
from microarray studies. However, several artifacts can confound
the analysis including: (i) amplification of undesired template
secondary to mispriming or annealing at inappropriate temperatures;
and (ii) susceptibility to RNA contamination with genomic DNA,
especially when collecting samples from tumor tissues (
2). Though
the problem of genomic contamination is partially addressed
by DNase treatment this method is often incomplete and its protracted
use often diminishes the sensitivity of detection. This is a
costly problem particularly when the detection of rare transcripts
in precious tissue samples is desired (
3).
Low cost methods for detecting fluorescent dyes which bind to double stranded DNA, such as SYBR Green, are most widely used and suitable for high throughput screening. Since these dyes are not sequence specific, careful consideration should be given to avoid generating extraneous amplicons. One of the obstacles to high throughput RT-PCR gene expression studies in which multiple unique transcripts are simultaneously measured in 96 or 384 well formats, is the necessity to individually optimize each assay for each target (4). Currently, the criteria for successful determination by quantitative RT-PCR require that: (i) the optimal amplicon should be located in a non repetitive region without segments of low complexity, (ii) the optimal amplicon size should be
100 bp to ensure the efficiency of Taq polymerase processivity, (iii) if possible, primers should be designed to flank intronexon borders or primers anneal at a splice junction to distinguish genomic DNA from cDNA template, and (iv) primers have similar melting temperatures with 2070% GC content (5,6). It is a laborious and error-prone chore to design RT-PCR primers that meet these requirements. Available resources for pre-designed primers are limited. RTPrimerDB (http://medgen.ugent.be/rtprimerdb/), an online database, provides experimentally verified primer sets for 2699 human and 487 mouse genes (7,8). PrimerBank (http://pga.mgh.harvard.edu/primerbank/) is a well known resource that covers most known human (33 741) and mouse (27 681) genes (9). However, its primer algorithm is not designed to span introns and is therefore more prone to amplify contaminating genomic sequences. Here we describe qPrimerDepot, a primer database for RT-PCR analysis of >99% of human (23 400) and mouse (18 733) RefSeq genes. These primers sets are designed to be used under uniform annealing temperatures to facilitate their application in large scale high throughput assays. Moreover, to reduce the noise from contaminating genomic DNA (6), over 90% of the primer sets are designed to produce amplicons bridging exon:exon junctions of intron-bearing genes.
 |
MATERIALS AND METHODS
|
|---|
Data processing
Sequences file (refMrna.zip) and intron/exon information tables
(refGene.txt.gz) of 23 463 human and 18 737 mouse RefSeq genes
(UCSC hg17 and mm6) were downloaded from UCSC genome browser
(
http://hgdownload.cse.ucsc.edu/).
To assure amplicons free of repetitive elements and sequences of low complexity (10), we utilized Biowulf, a high-performance Linux cluster at the National Institutes of Health, to mask the repetitive elements using the RepeatMasker application with built-in MaskerAid (11).
Primer3 (12) was used to design primers for each RefSeq entry, with the following parameters: for intronless genes (5.5% of human RefSeq genes and of 12.4% of mouse RefSeq genes), primers were set to be between 17 and 27 bp with 20 bp as optimum, and melting temperature was set to be between 57 and 63°C with 60°C as optimum, all other parameters, such as PRIMER_SELF_ANY and PRIMER_SELF_END, were set to default (8.0 and 3.0, respectively) to assure low self-complementarity. All cDNA amplions were 90150 bp in size to ensure Taq polymerase efficiency. For 99% of intron-bearing genes (94.5% human genes and 88.6% mouse genes bear at least one intron), primers were designed to flank or cross an exon-intron border in which the intron was one of the top three largest in the gene of interest. Thus, contamination by genomic DNA would generate either a longer product, which can be detected by melting curve analysis, or no product if the contamination template length (intron > 3 Kb) is too long for Taq polymerase to traverse during the extension period.
The BLAST algorithm was used via the NIH biowulf Linux cluster to evaluate all primers against corresponding RefSeq databases. The criteria for possible mis-priming requires that both primers have at least 15 matches in another RefSeq entry (i.e. expectation value, e < 1) (13,14). The BLAST result revealed that 891 of human and 420 of mouse primers may mis-prime to other RefSeq sequences. Sequence alignments of query and hit RefSeq using the BLAST2 algorithm (15) were performed and primer pairs which had <80% identities were filtered out of the database. Annotations are presented in the user interface for the individual primer sets that could mis-prime another RefSeq gene with >80% identity. The sources of these mis-primed RefSeq will vary, but may include redundancy within the RefSeq database, transcript variants and paralogs of high sequence similarity. Each of these possibilities can be assessed by a direct link that is provided to in silico PCR (http://genome.ucsc.edu/cgi-bin/hgPcr?command=start) for all primer pair sets. This link allows the user to rapidly identify amplicon locations in the mouse and human genomes so that primer specificity can be visually assessed and validated.
qPrimerDepot can be accessed at http://primerdepot.nci.nih.gov/ or http://mouseprimerdepot.nci.nih.gov/ by querying the database with a RefSeq ID or a gene name. Batch query service is available upon request if user provides standard gene name or accession number. Flat files and MySQL dump file which have all primer information are also available upon request.
Experimental validation
Reverse transcription was applied with Omniscript RT Kit following manufacturer's protocol (Qiagen). A 20 µl RT reaction included 2 µg Universal reference RNA (Stratagen), 1 µM Oligo-dT primer, 2 µl of 10x RT buffer, 0.5 mM each dNTP, 10 U of RNase inhibitor, 4 U of Omniscript Reverse Transcriptase, and DEPC-treated water. The reaction mix was incubated at 37°C for 60 min. After the reaction, the mix was diluted 1:5 with water for PCR analysis.
Primer sequences were extracted from our database and synthesized by Integrated DNA Technologies (Coralville, IA, USA). Quantitative RT-PCR was carried out in a DNA Engine Opticon-2 Real Time PCR Detection System (MJ Research). In brief, each 20 µl reaction mix comprises 0.3 µM primers (both 5' and 3' primers), 1 µl template from reverse transcription and 10 µl 2 x QuantiTect SYBR Green PCR Master Mix (Qiagen). Each reaction mix was incubated at 95°C for 15 min, 40 cycles of 95°C for 15 s and 60°C for 1 min. A melting curve analysis which read every 0.3°C from 65 to 95°C was followed to assess the homogeneity of a PCR product. Real-time PCR results were analyzed using the software provided by the manufacturer.
 |
RESULTS AND DISCUSSION
|
|---|
Our database comprises pre-designed primers for 42 133 mouse
and human RefSeq genes (
Table 1). For most genes three unique
sets of primers are provided (96.3% of total). The database
provides a simple user interface where the user may enter either
the HUGO approved gene symbol or the RefSeq gene identifier
(
Figure 1). The database graphic output provides information
on the primary transcript location, number of introns, primer
sequence, primer length, GC%, amplicon size, and genomic amplicon
size. Also a direct link is provided for location of the genomic
amplicon by
in silico PCR (
Figure 2).
To experimentally evaluate the primer quality, 288 genes were
arbitrarily selected from a list of genes known to function
in the immune response. 288 primer sets were retrieved from
the database and synthesized in 96-well plates. Universal human
reference RNA was reverse transcribed and used as template in
PCR to examine the quality of the primers.
Given the variation of transcript abundance, melting curve analysis followed by gel electrophoresis has been suggested to verify RT-PCR products (6). Melting curve analysis revealed that 94.1% generate unique product. Visualization by the less sensitive ethidium bromide stain shows that >70% of the primer sets produce an amplicon of the correct molecular weight that will amplify and be detected as a single species by quantitative PCR (Figure 3). Several of the failures detected by gel electrophoresis are likely due to very low abundance transcripts in the universal RNA, imperfect primer design, unanticipated high secondary mRNA structure, or erroneous exon annotation in UCSC Genome Browser. Approximately 88.5% of primer sets produced no product in the absence of reverse transcriptase and the remaining sets produced detectable product only beyond 34 cycles of amplification possibly, due to primer dimers.
The resistance of most qPrimerDepot primer sets to contaminating
input genomic DNA is illustrated in
Figure 4. Here the real-time
amplification profiles of three intron-bearing genes (VEFG,VEGFB
and VEGFC) was compared to that of three non intron-bearing
genes (XCR1, SSTR4 and MC1R) after challenge with increasing
concentrations of contaminating genomic DNA (0.5500 pg/µl).
As demonstrated in
Figure 4, all three intron-bearing genes
show robust resistance to >500 pg/µl of input genomic
DNA. This is in stark contrast to the three non intron-bearing
genes where as little as 5 pg/µl produces a significant
false signal.

View larger version (32K):
[in this window]
[in a new window]
[Download PowerPoint slide]
|
Figure 4 Real-time PCR amplification profiles generated using qPrimerDepot primer sets for non intron-bearing (XCR1, SSTR4, MC1R) and intron-bearing (VEFG, VEGFB, VEGFC) genes compared after the addition of increasing amounts of contaminating genomic DNA.
|
|
 |
CONCLUSION
|
|---|
Taking advantage of the intron/exon inventory of RefSeq genes
and Primer3, a paradigm primer design tool, we designed primers
which are contamination resistant for 99% of human and mouse
RefSeq genes (
Table 1). Since the majority of the primer sets
will amplify desired templates under unified annealing temperatures,
high throughput multiplex analysis is achievable at a reasonable
cost. Empirical screening and validation of primer set performance
conservatively suggests that 7090% of the primer set
designs are likely to perform effectively right out of
the box with no need to adjust the conditions of amplification.
Therefore, qPrimerDepot is a valuable resource for qRT applications,
especially in those circumstances requiring high throughput
detection of rare transcripts in curated and/or patient-derived
samples that often contain unavoidable contamination with genomic
DNA.
 |
ACKNOWLEDGEMENTS
|
|---|
This project has been supported by funds from the Intramural
Research Program of the NIH, National Cancer Institute, Centers
for Cancer Research and the National Institute on Aging. Funding
to pay the Open Access publication charges for this article
was provided by the Intramural Research Program of the NIH,
National Cancer Institute, Centers for Cancer Research.
Conflict of interest statement. None declared.
 |
REFERENCES
|
|---|
- Walker, N.J. (2002) A technique whose time has come Science, 296, 557559[Abstract/Free Full Text]
.
- Kitlinska, J. and Wojcierowski, J. (1995) RNA isolation from solid tumor tissue Anal. Biochem, . 228, 170[CrossRef][ISI][Medline]
.
- Bustin, S.A. (2002) Quantification of mRNA using real-time reverse transcription PCR (RTPCR): trends and problems J. Mol. Endocrinol, . 29, 2339[Abstract]
.
- Shaffer, C. (2005) PCR gains momentum with new applications Genetic Engineering News, 25, 2429
.
- Bustin, S.A. (2000) Absolute quantification of mRNA using real-time reverse transcription polymerase chain reaction assays J. Mol. Endocrinol, . 25, 169193[Abstract]
.
- Ausubel, F.M., Brent, R., Kingston, R.E., Moore, D.D., Seidman, J.G., Smith, J.A., Struhl, K. (2005) Current protocols in molecular biology New York John Wiley & Sons
.
- Pattyn, F., Speleman, F., De Paepe, A., Vandesompele, J. (2003) RTPrimerDB: the Real-Time PCR primer and probe database Nucleic Acids Res, . 31, 122123[Abstract/Free Full Text]
.
- Pattyn, F., Robbrecht, P., De Paepe, A., Speleman, F., Vandesompele, J. (2006) RTPrimerDB: the real-time PCR primer and probe database, major update Nucleic Acids Res, . 34, D684D688[Abstract/Free Full Text]
.
- Wang, X. and Seed, B. (2003) A PCR primer bank for quantitative gene expression analysis Nucleic Acids Res, . 31, e154[Abstract/Free Full Text]
.
- Jurka, J. (2000) Repbase Update: a database and an electronic journal of repetitive elements Trends Genet, . 16, 418[CrossRef][ISI][Medline]
.
- Bedell, J.A., Korf, I., Gish, W. (2000) MaskerAid: a performance enhancement to RepeatMasker Bioinformatics, 16, 10401041[Abstract/Free Full Text]
.
- Rozen, S. and Skaletsky, H. (2000) Primer3 on the WWW for general users and for biologist programmers Methods Mol. Biol, . 132, 365386[Medline]
.
- Altschul, S.F., Gish, W., Miller, W., Myers, E.W., Lipman, D.J. (1990) Basic local alignment search tool J. Mol. Biol, . 215, 403410[CrossRef][ISI][Medline]
.
- Wang, X. and Seed, B. (2003) Selection of oligonucleotide probes for protein coding sequences Bioinformatics, 19, 796802[Abstract/Free Full Text]
.
- Tatusova, T.A. and Madden, T.L. (1999) BLAST 2 S, a new tool for comparing protein and nucleotide sequences FEMS Microbiology Lett, . 174, 247250[CrossRef][ISI][Medline]
.